Before launching an imported medical device in China, connect the product authorization with the parties that will import, store, sell and support it. A distribution agreement should identify who performs each task and which records show that the task was completed.
This launch checklist is designed for manufacturers and commercial teams preparing discussions with regulatory and contract advisers. It separates product status from the qualifications and responsibilities of the businesses handling the device.
Start with a product-status sheet
Record the model, intended use, classification, registration or filing reference and the version of the instructions and labeling planned for China. Compare these with the actual goods proposed for shipment. Keep any change assessment beside the product record rather than assuming an overseas update automatically carries across.
The Medical Device Supervision and Administration Regulations distinguish filing for Class I devices from registration for Class II and III devices. Imported products have their own application route. An overseas marketing authorization is not a substitute for checking the China product record and its scope.
Map the parties by function
| Function | Assignment to document |
|---|---|
| Overseas product owner | Technical information, authorization and product changes |
| China regulatory contact | Required local role and communications |
| Importer | Shipment documents and import coordination |
| Distributor and storage provider | Operating qualifications and handling records |
| Service and complaint contact | Installation, support and escalation responsibilities |
One business may perform several functions. Verify each function rather than treating a distributor's appointment as evidence that every activity is covered. Ask for the relevant licenses, filings and operating scope where applicable.
Translate quality duties into the agreement
Specify the product and territories covered, storage and transport arrangements, traceability records and access to documents. Identify who may appoint a subdistributor and how qualification checks are recorded. Separate title and payment terms from responsibilities for product handling.
The device regulations and distribution-supervision measures impose operating requirements according to the activity and product class, with specified exceptions. Confirm the applicable route for each participant. A commercial contract can allocate work between parties without eliminating their statutory responsibilities.
Rehearse a complaint or recall handoff
Choose a hypothetical complaint and trace it from the customer to the manufacturer and responsible China contact. Identify who holds the batch or serial information, who can quarantine stock and how field records will be obtained. Agree escalation contacts and internal response targets without presenting them as universal statutory deadlines.
Record how returned goods, samples and disputed products will be identified and preserved. If the channel changes, establish who retains historical records and continues to handle open complaints.
Make launch readiness a recorded decision
- Product status and shipment scope checked.
- Each participant's role and qualifications reviewed.
- Quality and commercial agreements executed.
- Storage, traceability and complaint contacts tested.
- Open regulatory questions assigned before shipment or sale.
The useful output is a responsibility map backed by documents. Where a qualification or product change remains unresolved, keep it visible as a launch condition rather than burying it in a general assurance that the distributor handles compliance.
Primary sources
- Medical Device Supervision and Administration Regulations, amended 2024
- Medical-device registration and filing measures
- Medical-device distribution supervision measures
Sources checked November 28, 2026. General preparation guidance; confirm the applicable requirements for the transaction, product and location.